Do you know anything about UV sterilization?
Ultraviolet radiation is a commonly used disinfection method for air and surface, and is also used in the disinfection of water and other liquids. But in the use of UV lamp, often because of not understanding its mechanism of action or neglect detection, can not make it play an effective role, can not reach the expected bactericidal effect. Here, ultraviolet sterilization to do a simple introduction.
1.Origin and principle of ultraviolet air disinfection
Origin of ultraviolet air disinfection. Early studies began in the 1920s. It was introduced in hospital operating rooms in 1936, and in schools for the first time in 1937.
2.The wavelength of ultraviolet light. The wavelength range is between 400 nm and 100 nm, which is divided into three bands A, B and C. Among them, uV-C band (290-100nm) ultraviolet has sterilization ability, called disinfection ultraviolet. Ultraviolet germicidal lamp is a special electric light source that directly uses ultraviolet light (central wavelength is 253.7nm) for disinfection purposes.
3.Disinfection principle of ultraviolet lamp. Ultraviolet disinfection lamp is a kind of low-pressure mercury lamp, which is irradiated by ultraviolet radiation emitted by mercury vapor at lower pressure (<10-2Pa). The ultraviolet disinfection lamp has two main spectral lines: 253.7nm wavelength and 185nm wavelength, and the peak wavelength is 253.7nm. These two wavelengths of ultraviolet light can play a very good sterilization role, the former can directly act on biological cell genetic material that is DNA, DNA damage and lead to bacterial death, and has the function of ozone decomposition; The latter can kill bacteria by interacting with oxygen in the air to produce strong oxidizing ozone.
4.The distinction of ultraviolet ray disinfection lamp and common fluorescent lamp, energy-saving lamp
Ordinary fluorescent lamp, energy-saving lamp lamp tube is ordinary glass, ultraviolet light can not be transparent, fluorescent powder absorption after the visible light; And the lamp tube of ultraviolet disinfection lamp uses the production of ultraviolet glass or quartz glass, ultraviolet light can pass through the glass tube wall transmission out. Ultraviolet lamp is a kind of incoherent light source, the intersection of two ultraviolet rays will not interfere. The radiation intensity of any point in the space radiation field formed by multiple ULTRAVIOLET lamps satisfies the superposition principle. The ultraviolet radiation intensity of a certain point in space is inversely proportional to the square of the distance from the ultraviolet lamp, so the disinfection effect of the ultraviolet lamp is mainly concentrated in the range of 1.0m.
Classification of ultraviolet lamp and technical requirements of ultraviolet lamp
1.According to the shape can be divided into double end lamp (S) and double end lamp (D) and from the ballast lamp (Z) three categories.
2.According to whether it contains ozone or not, it can be divided into ozone containing (represented by Y) and ozone free (represented by W).
3.The technical requirements of ultraviolet lamp mainly regulate the technical requirements of the following aspects :(1) medical electrical safety requirements; (2) Product performance and safety requirements, mainly ozone residue or leakage requirements, and ultraviolet exposure requirements; (3) Health and safety indicators, adding the evaluation of disinfection effect; (4) Environmental testing requirements; (5) Improve the original test method.
Ultraviolet lamp and other electronic products, in the installation and the use of the future have to pay attention to the matter, regular maintenance to ensure the service life of ultraviolet lamp. Several problems should be paid attention to in the use of UV germicidal lamp:
1.It is strictly prohibited to frequently start the uv lamp, that is, to reduce the number of switches, especially in a short period of time, to ensure the life of the uv lamp.
2.Regular cleaning, keep clean: the dirt on the surface of the ultraviolet lamp will affect the penetration of ultraviolet light, thus affecting the bactericidal effect, so it needs to be cleaned regularly, wipe the lamp with alcohol cotton ball or gauze.
3.When replacing the lamp tube, unplug the lamp socket first, pull out the lamp tube, and then carefully insert the clean new lamp tube into the sterilizer, and then plug in the power supply. Do not touch the uv lamp directly with your hands. If you find fingerprints or dust, wipe it clean before use, otherwise it will affect the bactericidal effect due to stains.
4.Prevent ultraviolet radiation: ultraviolet radiation has a powerful killing to bacteria, and also has certain harm to the human body. When starting the disinfection lamp, avoid direct irradiation to the human body, and use protective glasses when necessary. Do not directly face the light source with your eyes, so as not to burn the eye membrane.
5.Power supply frequency: AC power supply. The radiation flux of the lamp varies with the frequency of the power supply. Therefore, the power supply frequency must be fully considered when using or testing the UV germicidal lamp.
6.Use standard ballasts: the quality of the ballast used for the UV lamp directly affects the radiation of the uv lamp connected in the circuit. When evaluating the technical index of uv lamp, the data measured by standard ballast must be convincing only under specified power supply conditions.
7.Ultraviolet lamp detection: the life of ultraviolet lamp is limited, the effective life of domestic ULTRAVIOLET lamp is generally 1000~3000h, and the service time of imported low-voltage high-energy lamp can reach 8000 ~ 12000h, medium pressure lamp can reach 5000 ~ 6000h. Therefore, it is necessary to establish a recording and monitoring system, and it is recommended that the test interval should not exceed 1 month in the laboratory with high frequency of use.
8.Ultraviolet lamp installation: the intensity of ultraviolet light decreases with the square of the distance from the light source, because the penetration capacity is very weak, so it must be close to the material being processed. Therefore, ultraviolet light for large open area of air disinfection is not too much effect, it is only suitable for local or regional disinfection. The ultraviolet sterilization effect is related to the irradiation time and distance, and the effect is better for long time and short distance. The uv lamp should be installed slightly above the head of the staff.
At present, by the sterilization rate to accurately calculate the number of uv lamps required by the production workshop is still relatively difficult, because it involves the number of air changes in the room, the height of the production workshop, the ground material, the reflection efficiency of the wall and roof, etc., the general production workshop uv lamp irradiation intensity is not less than 70μW/cm2, In order to ensure adequate number of tubes, here is an empirical value for reference, generally can be installed every 7 to 10m² a 30W UV lamp.
The bactericidal action of ultraviolet light
Ultraviolet sterilization is surface sterilization, with ultraviolet sterilization lamp irradiation indoor air, can prevent bacterial pollution and sterilization effect. It is the more effective method that air disinfect uses generally at present, but the penetrating ability of ultraviolet ray is weaker, common glass and dust can affect its radiative sterilization effect, do not have sterilization effect to the part that does not have irradiation.
In addition, although ultraviolet lamp disinfection is convenient and practical, it can not completely sterilize, especially to the bacteria spores killing effect is very poor. Therefore, the role of ultraviolet is very limited, the requirements of enterprises on the production environment can not excessively rely on the sterilization effect of ultraviolet, but also pay attention to the standards of health links and operation.
In the production and processing workshop, the power switch of the UV lamp is set
Under normal circumstances, the ultraviolet lamp of the workshop is half an hour before going to work to an hour or after work by the personnel on duty to open, the staff should wash their hands and change clothes into the workshop under the circumstance of closing the ultraviolet lamp when going to work, when the light is insufficient, can open the fluorescent lamp to work.
So, when power supply is designed, the switch of ultraviolet lamp and fluorescent lamp wants to separate circuit, had better use different color or mark to distinguish power supply switch.
In the production and processing workshop, can the UV lamp be installed with protective devices?
In many food processing enterprises, the worktables of production workshops, open production lines and lighting equipment above exposed food and raw materials are generally equipped with protective devices. However, due to the poor penetration of ultraviolet light, the protective device will weaken the bactericidal effect or even lose the bactericidal effect.
Therefore, the ultraviolet lamp in the production workshop can not be equipped with protective devices. Because it is impossible to install protective devices, the uv lamp cannot be installed directly above the table, so as not to scatter glass fragments among the food in the event of an explosion. Plus uv damage to the human body, so the best use of uv lamp should be:
Before or after work to open, generally open 30 minutes after the close of 20 ~ 30 minutes to enter, so as to achieve sterilization effect, and play a protective role on the operator's body, but also reduce the production process of ultraviolet lamp explosion, resulting in glass fragments scattered in the possibility of food.
Therefore, only by understanding the sterilization effect of ultraviolet light, correctly installing, using and maintaining ultraviolet light, can we achieve sterilization effect in the production workshop, effectively purify the air, so as to prevent the production environment from being polluted or cross-polluted.
Leave a Reply
- INVITATION OF DUBAI LIGHTING FAIR FROM ZJESL
- How to Choose a Reliable Professional LED Lighting Supplier — Taking ZJESL as an Example
- Speed, Precision, Steadiness | ZJESL 2025 Line Skills Challenge
- Discover the Versatility of ATHENA Panel Lights: A Lighting Solution for Every Space!
- Lighting Up Families | ZJESL's Gift of Warmth to Employees